Equipments

Biochemistry & Immunology
  • Cobas c-311 (Roche Diagnostics)

    Highly reliable system with state-of-the-art user friendly software with broad parameter portfolio of more than 120 assays and applications available including DATs, Therapeutic Drug monitoring, specific proteins and whole blood HbA1c

    Throughput

    Up to 300 tests/hour; ISE: 150 samples/h (corresponding to 450 tests/h)

    Unique reagent concept

    No preparation or mixing required

    High system reliability

    Programmable automated maintenance functionalities

    Increased efficiency

    Consolidation of 98% or more of the serum work area testing on a single tube

    Quality of results

    Results you can trust that are right the first time

    Optimized workflow

    Comprehensive IT solution, Workflow efficiency and reduced complexity, Equivalent, comparable results across all cobas analyzers

    Download Technical Specification
  • Cobas e-411 (Roche Diagnostics)

    Novel Electrochemiluminescence (ECL) technology system provides superior analytical performance. Increased sensitivity means that extremely low levels of antigen, as well as subtle changes in levels, can be detected. The customized keyboard and easy-to-learn software make training and operation simple and keep user involvement to a minimum. Unique programming-by-loading concept Barcode-based data entry is carried out automatically by loading reagents, controls and calibrators onto the system – a rapid, robust and safe procedure. ECL is a unique and highly sensitive luminescence (light) detection system that amplifies the required signal and reduces any unwanted signals to deliver unmatched low-end sensitivity and broad dynamic measuring ranges. STAT facilities for urgent samples cobas e 411 disk system features two STAT sample positions that can be accessed at any time, delivering results rapidly in response to clinicians‘ requests .

    Three ways to unmatched performance:
    • Wide measuring ranges reduces the amount of tests rerun due to out of range results examples:
    • Estradiol
    • Progesterone
    • total-PSA
    • High analytical sensitivity enables the use of innovative tests and requires less sample volume examples: Troponin T 4th gen. with
    • Nine minutes STAT applications deliver unmatched turnaround time for emergency samples like hCG+ß, Troponin T 4th Gen., CK-MB, Myoglobin, PTH*
    Download Technical Specification
  • AVL 9180 Electrolyte analyser

    The AVL 9180 Series Electrolyte Analyzer is a single, stand alone unit, ensures unbeatable precision & accuracy that brings a ravellation in diagnostics. The innovative AVL 9180 Series give you a choice of seven different interchangeable electrolyte configurations to fit immediate and future testing needs of physicians.

    Feature Highlights
    • Interchangeable electrodes
    • Single SnapPak for all configurations
    • SnapPak sensor
    • Programmable correlation factors
    • Fastest turn around time to the tune of 2 minutes

    Download Technical Specification
  • Beckmann Coulter Access 2

    Coming Soon !!

    Download Technical Specification
  • Hitachi 902
  • Erba Chem 5
    • Versatile analytical options such as Endpoint (Linear and non-linear)- Kinetic and Fixed time- in Monochromatic and Bichromatic modes.
    • Displays- Prints and Memorises graphs of all linear and non-linear reactions
    • Most economic system using only 200-500 reagents per test
    • 128 totally open Test programmes directly selectable through keyboard
    • Built-in Self-Diagnosis ensures simple and safe maintenance
    • User-friendly software guides the operator step by step
    Download Technical Specification
  • Cobas 4000 analyzer series
Haematology & Clinical Pathology
  • Sysmex XS 1000i (5-part cell counter)

    Intuitive software, Barcoded reagent management,Comprehensive QC information, On-board help key for trouble menus

    Download Technical Specification
  • Sysmex KX-21 (3-part cell counter)

    With its simplified operation, the KX-21N is an ideal hematology analyzer for a clinic satellite laboratory or research testing. It provides a CBC with 17 reportable parameters and 3-part WBC Differential, which includes an Absolute Neutrophil Count (ANC). The results include histograms for WBC, RBC and PLT. The system provides a high level of accuracy through the use of automatic floating discriminators. Built on reliable Sysmex technology, it features a simple start-up menu and single button selection for sampling and daily maintenance with a compact, space-saving design.

    Reliability, Accuracy and Simplicity
    • Same direct current detection method as Sysmex high-end systems to provide accurate, comparable results
    • Minimal training required
    • Simple menus
    • Push button technology
    • Non-toxic, biodegradable reagents
    • Reliable hardware and results
    • Network capability via LIS
    Download Now
  • Beckmann Coulter Act Diff2 (3-part cell counter

    The COULTER ACT diff2 hematology analyzer is an affordable, easy-to-use system that is ideal for any volume laboratory. As a fully automated system, the ACT diff2 offers a CBC and 3-part Coulter histogram differential for consistently accurate results. This compact analyzer provides closed vial sampling to maximize safety and efficiency in your lab. It requires a small sample volume in both open and closed analysis modes, offers a wide operating range and provides multiple output formats. Wide operating ranges, extended platelet counting and linearity of WBC and PLT to zero speed turnaround times of the most critical values, Triplicate counting and patented sweep flow technology and aperture monitoring assure accurate results

    Download Technical Specification
  • ESR analyzer

    Automated analyzer with inbuilt mixer and printer Readings perfectly correlated with Westergren method ESR analysis in 20 minutes by sedimentation kinetics Minimum sample requirement of 1± 0.2 ml RS232 C interface (Bidirectional data transfer) Inbuilt QC program Memory storage of 4 batches (80 samples) Automated temperature correction to 18 ° C Evacuated ESR tubes prefilled with sodium citrate External barcode reader port...

    Download Technical Specification
  • Humaclot Junior

    Compact, maintenance-free channel 1 coagulation instrument, that is able to perform nearly all coagulation parameters with vast accuracy & precision.

    Parameters commonly performed:
    • Prothrombin Time (PT)
    • Activated partial thromboplastin time (aPTT )
    • Thrombin Time (TT)
    • Fibrinogen (FIB)
    • D-Dimer (DD)
    • Protein C (PC)
    • Antithrombin (AT3)
    • Factors (FAC)
    Download Technical Specification
  • Biorad D-10

    Compact High performance liquid Chromatography system allows comprehensive, fully automated diabetes monitoring and β-thalassemia testing on a single platform; It is an ideal instrument for HbA1C & HbA2/F electrophoresis.

    Download Technical Specification
  • Roche Urisys 1100 Urine analyser
    Automated testing for convenience and consistency

    With simple, 1-button operation, the Urisys 1100 Urine Analyzer makes urine testing fast, easy and accurate.

    • Automated test eliminates visual inspection and waiting for results
    • Automatic result printout ensures consistent, accurate results
    • Optional results downloading, including device ID, operator ID and patient ID, eliminates manual data entry errors
    • Optional operator lockout function helps facilitate regulatory compliance
    • Simple cleaning minimizes maintenance needs
    • Flexible strip options: Chemstrip® 10 MD, Chemstrip 7 or Chemstrip 5 OB test strips
    • Error messages alert user to issues that could affect accuracy of results
    Download Technical Specification
GeneXpert cepheid Molecular diagnostic system
    • Gene expert is a cartridge based fully automated real time-PCR.
    • Automatic Nucleic acid amplification technology (NAAT).
    • Its automation includes Nucleic acid (DNA or RNA) isolation, purification, cDNA preparation (in case of RNA only), amplification and optical detection of target amplified sequence.
    • Automatic RT-PCR based NAAT.
    • Easy to use.
    • Minimum resources for maximum output.
    • Same machine can be used for all Genexpert assays.
    • WHO recommended gold stranded technology.
    • Fast and accurate for molecular diagnosis.
    • No batch requirement.
    • Modules are independent in function, ie. Same or different assay can be performed at same or different time period.
    • No skilled technical staff required.
    • Hands on time: very less ie. Minimum human handling required.
    • Less assay time required as compared to conventional technology.
    • Less space requirement.
    • Easy to handle and movable.
    • Less chance of contamination since it is fully automatic.
    • Easily integrated into any lab to improve workload and workflow optimization.